26/68 Transport and storage
Bosch Rexroth AG, A20V(L)O Series 1, RE 93100-01-B/2019-09-10
6.2 Storing theaxial piston unit
• Storage areas should befree ofcorrosive materials and gases.
• To prevent damage tothe seals, do not operate ozone-forming equipment
(e.g.mercury-vapor lamps, high-voltage equipment, electric motors, sources
ofelectrical sparks and/orelectrical discharge) instorage areas.
• Storage areas should bedry.
Recommended relative humidity ≤60%.
• Ideal bearing temperature: +5°C to+20°C.
• Minimum storage temperature: −50°C.
• Maximum storage temperature: +60°C.
• Keep out ofdirect sunlight.
• Do not stack axial piston units and store them inashock-proof manner.
• Do not store theaxial piston unit onthe drive shaft orassembled parts,
e.g.sensors orvalves.
• For further storage conditions, see Table 7.
▶ Check theaxial piston unit monthly toensure proper storage.
The axial piston units come incorrosion protection packaging
(corrosionprotectionfilm) provided atthe factory.
Table 7 lists themaximum permissible storage times for anunpackaged axialpiston
unit asper data sheet 90312.
Table 7: Storage time with factory corrosion protection
Storage conditions Standard corrosion protection Long-term
corrosion protection (optional)
Closed, dr
y room, uniform
temperature between +5°C
and +20°C. Undamaged
and closed corrosion
protectionfilm.
Maximum 12 months Maximum 24months
The warranty will bevoided iftherequirements and storage conditions are not
observed orafter expiration ofthemax. storage time (see Table 7).
How toproceed once themax. storage time elapses:
1. Check theentire axial piston unit for damage and corrosion prior toinstallation.
2. Perform atest run tocheck theaxial piston unit for proper functioning and
leak-tightness.
3. Ifstorage time exceeds 24months, replace theshaft seal.
Once themax. storage time has elapsed, we recommend that you have
theaxialpiston unit checked byyour BoschRexroth service partner.
For questions regarding repair and spare parts, contact your proper BoschRexroth
service partner ortheservice department ofthemanufacturer's plant oftheaxial
piston unit, see chapter 10.5 "Spare parts" onpage56.
Requirement
After delivery