Commissioning 49/68
RE 93100-01-B/2019-09-10, A20V(L)O Series 1, Bosch Rexroth AG
8 Commissioning
WARNING
Danger while working inthe danger zone ofamachine/system!
Danger tolife, risk ofinjury orserious injury!
▶ Pay attention toand eliminate potential danger sources before commissioning
theaxial piston unit.
▶ Make sure noone isinthe danger zone ofthemachine/system.
▶ The emergency stop button for themachine/system should bewithin
theoperator's reach.
▶ Always follow theinstructions ofthemachine/system manufacturer during
commissioning.
CAUTION
Commissioning animproperly installed product!
Risk ofinjury and property damage!
▶ Make sure all electrical and hydraulic ports are connected orplugged.
▶ Commission only afully installed, fully functioning product with original
accessories from BoschRexroth.
8.1 Initial commissioning
During all commissioning work onthe axial piston unit, observe thegeneral safety
instructions and intended use detailed inchapter2 "Safety instructions"
onpage9.
▶ Connect thepressure gauge for theworking pressure, case pressure and suction
pressure tothe specified measuring points onthe axial piston unit orinthe
hydraulic system, tocheck thetechnical data atfirst operation.
▶ During commissioning, monitor thetemperature ofthehydraulic fluid inthe
reservoir toensure that itlies within permissible viscosity limits.
8.1.1 Filling theaxial piston unit
Professional filling and air bleeding isnecessary toprevent damage tothe
axialpiston unit and tomaintain proper function.
Usually, thecleanliness level ofcommercial hydraulic fluids isinsufficient for our
components. These hydraulic fluids must befiltered during filling using
anappropriate filter system tominimize solid particle contamination and water
inthe system.