46/68 Installation
Bosch Rexroth AG, A20V(L)O Series 1, RE 93100-01-B/2019-09-10
To connect theaxial piston unit tothe hydraulic system:
1. Remove theprotective plugs and/or threaded plugs from theports where
theconnections should bemade according tothe hydraulic circuit diagram.
2. Make sure thesealing surfaces ofthehydraulic ports and functional surfaces are
not damaged.
3. Use only clean hydraulic lines orflush them before installation.
(Observechapter7.5 "Performing flushing cycle" onpage48 when you flush
out theentire system.)
4. Connect thelines inaccordance with theinstallation drawing and themachine
orsystem circuit diagram. Check that all ports are connected orplugged with
threaded plugs. With inside-reservoir installation, thehousing oftheaxial
piston unit must befilled before fitting thelines and filling thereservoir with
hydraulicfluid.
5. Properly tighten thefittings (observe tightening torques!). Mark all properly
tightened fittings, e.g. with apermanent marker.
6. Check all pipes and hose lines and every combination ofconnecting pieces,
couplings orconnecting points with hoses orpipes toensure they are insafe
working condition.
7.4.9 Electrically connecting theaxial piston unit
NOTICE
Short circuit due topenetrating hydraulic fluid!
Fluid can penetrate theproduct and cause ashort circuit!
▶ Do not install axial piston units with electric components (e.g. electric controls,
sensors) inareservoir below thefluid level (inside-reservoir installation) unless
they have been explicitly released for use under hydraulic fluid, e.g. HS5M.
Information on the HS5M can be found in data sheet 92076.
The proportional valve can be positioned separately in the system and connected
via the designated ports X
1
and X
2
of the pump. The unit can be installed in the
reservoir together with the directly mounted position transducer. Approved for
HLP fluids DIN 51524.
The machine/system manufacturer isresponsible for electric control layout.
Electrically controlled axial piston units must beconnected inaccordance with
theelectrical circuit diagram for themachine/system.
For axial piston units with electrical control and/or mounted sensors,
observetheinformation indata sheet 93100, e.g.:
• Permissible voltage range
• Permissible current
• Correct pin assignment
• Recommended electrical control units
Procedure