Maintenance and repair 55/68
RE 93100-01-B/2019-09-10, A20V(L)O Series 1, Bosch Rexroth AG
Table 20: Inspection schedule
Tasks tobe performed Interval
Hydraulic system Check hydraulic fluid level inthe reservoir. Daily
Check theoperating temperature under comparable load
condition atthedrain port and inthe reservoir.
Weekly
Conduct hydraulic fluid analysis: Viscosity, aging and
contamination
Yearly orevery
2000 operating
hours (whichever
occursfirst)
Check filter.
The replacement interval may vary depending onthe
cle
anliness ofthehydraulic fluid. We recommend using
acontamination indicator.
Yearly orevery
1000 operating
hours (whichever
occursfirst)
Axial piston unit Check axial piston unit for leakage.
Early detection ofhydraulic fluid loss can help tofind
fault
s onthe machine/system and rectify them. This
iswhy BoschRexroth recommends always keeping
theaxial piston unit and system clean.
Daily
Check axial piston unit for unusual noise development. Daily
Check mounting elements for tight seating.
All fasteners have tobe checked when thehydraulic
sy
stem isswitched off, depressurized and cooled down.
Monthly
10.3 Maintenance
The axial piston unit islow-maintenance when used asintended.
The service life oftheaxial piston unit isheavily dependent onthe quality
ofthehydraulic fluid. This iswhy we recommend changing thehydraulic fluid atleast
once per year orevery 2000 operating hours (whichever occurs first), orhaving
itanalyzed bythehydraulic fluid manufacturer oralaboratory todetermine its
suitability for further use.
The service life oftheaxial piston unit islimited tothe service life ofthebearings
used. You can ask your local contact person about service life based onload cycle.
You can find their contact information at
www.boschrexroth.com/addresses
Based onthese details, amaintenance interval should bedetermined
bythesystem manufacturer for thereplacement ofthebearings and included
inthe maintenance schedule ofthehydraulic system.