11.2 Commissioning steps
To commission the device, proceed as follows:
1. Mount the control.
For details, refer to chapter 10 "Mounting, demounting and electric instal-
lation" on page 16.
2. Connect the voltage supply to the XD1 connection of the control.
Refer to chapter 10.7.2 "Voltage supply for the control" on page 26.
3. The XM4x control is available in the following firmware variants
3.1 XM4x with initial firmware, (XM4x00.01-...)
For more information on how to commission the XM4x control with the
initial firmware, refer to chapter 12.2 "XM4x initial firmware" on page
40.
Control malfunction due to control switch-off
during initialization
NOTICE
Note that hardware is initialized after switching on the control and after instal-
ling the system firmware with subsequent reboot. An internally programmable
function block is loaded. After loading, the LED display "ON" at the voltage plug
is green.
Wait till completion. Do not switch off the control. This procedure has to be
completed. Subsequently, continue the commissioning.
11.3 Establishing a connection to the engineering PC via the USB
device interface "XF31"
Instead of using the Ethernet interface "XF5" to commission the control or to
use the commissioning tool "IndraControl First Touch", use the connection XF31.
Connect the USB interface of your computer to the USB device connection
"XF31" via a common USB data and charging cable. Upon the initial connection,
the respective device driver (USB Remote NDIS) is installed on the PC.
Even though the computer and the control communicate via Ethernet, it is only a
point-to-point connection.
The IP address of the connection
"XF31" on the control is
192.168.234.234.
The IP address cannot be changed.