EasyManua.ls Logo

Bosch Rexroth IndraMotion MLC - Mechanical strength; Contamination level acc. to EN 60664-1; Overvoltage category acc. to EN 60664-1

Bosch Rexroth IndraMotion MLC
94 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
In operation Transport Storage
Mechanical
strength
Max. Vibration:
Frequency range:
10 Hz to 150 Hz
Excursion:
0.75 mm at 10 Hz to 57 Hz
Acceleration:
1 g at 57 Hz to 150 Hz
Acc. to EN 60068-2-6
Max. Shock:
15 g 11 ms
Acc. to EN 60068-2-27
Max. Shock:
15 g 11 ms
Acc. to EN 60068-2-27
Contamination
level acc. to EN
60664-1
2 2 2
Overvoltage
category acc.
to EN 60664-1
2
Tab. 6-1: Ambient conditions
Defective product due to gases jeopardizing
functions
NOTICE
Due to the risk of corrosion, avoid sulphurous gases (e.g. sulphur dioxide (SO
2
)
and hydrogen suphide (H
2
S)). The product is not resistant against these gases.
The device is not resistant to gas jeopardizing the function [sulphur
dioxide (SO
2
), hydrogen sulphide (H
2
S)].
Failure of the product due to contaminated air
NOTICE
The ambient air must not contain acids, alkaline solutions, corrosive agents,
salts, metal vapors and other electrically conductive contaminants in high
concentrations
The devices to be installed into the housing and installation compartments
must at least comply with the degree of protection IP 54 according to DIN EN
60529.
The device shall be provided in a suitable fire enclosure in the end-use
application.
IndraControl VPB 40.4
Bosch Rexroth AG
Ambient conditions
DOK-MLC***-INDRACTRLV4-IT02-EN-P
9/87

Table of Contents

Related product manuals