4. Connect.
Strip cable jacket 35 ... 40 mm, wires 6 mm and connect wires L1-L3 and
PE in the plug insert according to the assignment plan. Use wire end fer-
rules according to connection wires. Tighten the clamping screws.
5. Close plug insert
Close plug insert and insert into connector housing. Tighten the housing
screw M3.
76/101
Assembly
MS2N Synchronous Servomotors
Bosch Rexroth AG R911347581_Edition 04