System > Holidays >
hOtime
Start / Stop Day
MENU 7-6-1
This menu allows you to program the duration of each
holiday stored in the panel. This is done by programming
the start and stop date for each holiday period. Holidays
can be as short as one day and as long as a week or more.
The following prompts will be shown when entering the
holiday parameters.
Sdd = Start Date (day of the month)
Smm = Start Month (month of the year)
Ehh = End Date (day of the month)
Emm = End Month (month of the year)
1. Enter your Master PIN + [MENU].
2. Enter [7] + [6] + [1] +[OK].
The keypad will display the Ho = prompt.
HO=
Enter the Holiday number you want to program, then
press [OK].
Sdd=01
Enter the day (01 - 31) of the month that the holiday
will start.
SMM=01
Enter the month (01 - 12) that the holiday will start.
Edd=01
3. Enter the day (01 - 31) of the month that the holiday
will end.
Emm=01
4. Enter the month (01 - 12) that the holiday will end.
Use the [←] and [→] keys to conrm programming and
then press [OK] to exit.
System > System Options >
L773
Keypad Hi/Lo Temp
MENU 7-7-3
The keypad Hi/Lo temperature allows you to program the
minimum (0 °C) and maximum (50 °C) temperatures the
keypad will monitor (tolerance = +/- 3 °C).
If the temperature falls below the minimum temperature,
or rises above the maximum temperature then the system
trouble indicator will be displayed.
1. Enter your Master PIN + [MENU].
2. Enter [7] + [7] + [3] + [OK].
The keypad will display the current Hi temperature
setting.
hi=20
3. Enter the required Hi temperature value in degrees
celcius.
LO=10
4. Enter the required Lo temperature value in degrees
celcius.
5. Press [OK] to save and exit, or press [MENU] to exit
without saving.
Your installer must activate temperature monitoring
for these parameters to take eect.