11-2
CONTROLLER TIPS (SOLID STATE)
COMPLAINT CAUSE REMEDY
Display reads FAIL 1. Faulty controller 1. Replace
Display reads HI
1. Faulty gas valve
2. Faulty contactor
1. Replace
2. Replace
Display reads PROBE
1. Wire polarity reversed
2. Faulty temperature sensor
probe
1. Rewire
2. Replace
Display reads CHEC
1. Gas valve OFF (1800GH)
2. Low gas pressure
(1800GH)
3. Poor air/gas mix (1800GH)
4. Main burner not on
(1800GH)
5. Loose gas valve wire
harness (1800GH)
6. Faulty flame sensor
(1800GH)
7. Faulty gas valve (1800GH)
8. Faulty contactor
(1600/1800E)
9. Faulty heating element(s)
(1600/1800E)
10. Open or faulty wall fuse
11. Pilot does not light
1. Turn ON
2. Check pressure
3. Adjust air shutter
4. See 5, 6, 7,8 and 11
5. Check connections
6. Replace
7. Replace
8. Replace
9. Replace
10. Check wall fuse or circuit
breaker
11. See GAS TIPS (1800GH)
broaster.com Manual #14680 3/99 Rev 5/14