4-6
If a button is not pressed
in ten seconds, the dis-
play will revert back to both the TIME
and TEMP displays flashing.
Change Cook Temperature:
Action: Press the TEMP button once.
Response: The TIME display will turn
off and the TEMP display will be flash-
ing.
Action: Key in the desired tempera-
ture setting and press the TEMP but-
ton to save the new setting.
If a button is not pressed
in ten seconds, the dis-
play will revert back to both the TIME
and TEMP displays flashing.
Activate/Deactivate Auto Comp:
Action: Press the AUTO COMP but-
ton once.
Response: AUTO COMP is enabled
when the AUTO COMP LED is on and
disabled when it is off.
Advance to Next Preset:
Action: Press the RESET button
once.
Response: The CYCLE COUNT dis-
play will change to “-1” and the pre-
sets for #1 will be displayed.
Repeat the process as described.
After the presets for #9 are displayed,
pressing the RESET button again will
cause the control to return to normal
operation.
WARNING DISPLAYS
HI - Display will flash HI if cooking oil tem-
perature exceeds 415
°F. Audible alert will
sound until cook/filter switch is turned OFF
or hi-limit trips. All controller functions and
heat source are disabled during this condi-
tion.
Cause: Faulty controller, gas valve
(1800GH Only) or contactor (1600/
1800E Only).
PROB - Display will flash PROB if there is a
problem with temperature sensor probe.
Audible alert will sound until cook/filter
switch is turned OFF. All controller functions
and heat source are disabled during this
condition.
Cause: Temperature sensor probe
faulty, polarity of probe wires reversed
or probe wire(s) loose.
CHEC - Display will flash CHEC if cooking
oil temperature does not rise 6
°F within the
first three minutes. Audible alert will sound
until cook/filter switch is turned OFF. All
controller functions and heat source are
disabled during this condition.
Cause: Faulty controller, heating ele-
ment(s) (1600/1800E Only), gas valve
(1800GH Only), contactor (1600/1800E
Only), probe or loose wiring.
CHEC could appear if
cooking oil temperature
is below 45°F. Turn cook/filter switch
OFF then to COOK for another two min-
ute heating period. This may have to be
repeated two or three times.
FAIL - Display will flash FAIL if controller
detects a fault within itself. Audible alert will
sound until cook/filter switch is turned OFF.
All controller functions and heat source are
disabled during this condition.
Cause: Faulty controller.
broaster.com Manual #14680 3/99 Rev 5/14