5-3
FUSE (1600/1800E)
Two 15 amp fuses protect the control and
filter circuits.
1. See ACCESS FOR SERVICE.
2. With needle nose pliers, disconnect
wire(s) from one end of fuse holder (4).
3. Check between two terminals of fuse
holder with an ohmmeter. Meter
should indicate a closed circuit. If not,
fuse may be faulty.
Fuse Replacement:
1. Remove end cap (5) and replace fuse
(6).
HEATING ELELEMENTS
(1600/1800E)
All elements heat the oil when thermostat
(1600 mechanical) or the solid state control-
ler calls for heat. If HEAT ON light is illumi-
nated for long periods of time, this may
indicate a faulty element or wire connec-
tion.
1. See ACCESS FOR SERVICE.
1600:
1800E:
Continued: