4-4
CONTROLLER PROGRAMMING
Check oil level before
turning cook/filter switch
to COOK.
Action: Turn cook/filter switch to
COOK.
Response: Temp Display alternates
between number values for cook tem-
perature, and LO (idle mode). LO will
disappear when oil temperature has
reached cook temperature value.
Time Display will show the set time in
minutes and seconds.
Set Temperature:
Action: Press Cook Temperature But-
ton twice within 5 seconds.
Response: Programming mode has
been entered. Flashing Temp Display
reads “###F.” (### = temperature value
ie: 360F)
Action: If desired, press keypad num-
bers to change displayed value. Press
Cook Temperature Button to enter new
value into memory.
Response: Controller returns to idle
mode.
Set Time:
Action: Press Cook Time Button
twice within 5 seconds.
Response: Programming mode has
been entered. Flashing Time Display
reads “##:##.” (##:## = time value ie:
08:00)
Action: If desired, press key pad
numbers to change displayed value in
minutes and seconds. Press Cook
Time Button to enter new value into
memory.
Response: Controller returns to idle
mode.
Set AUTO COMP (Automatic Time Com-
pensation):
Action: Press and hold AUTO COMP
Button for 3 seconds.
Response: Green light will toggle on
or off.
Read Actual Temperature:
Action: Press and hold Temp Button
for 3 seconds.
Response: Temp Display will show
actual oil temperature and will vary as
cooling and heating takes place.
Action: Press Temp Button to return
to set point display.
Reset Cycle Counter:
Action: Press Reset Button twice in 5
seconds.
Response: Display will return to a
setting of “00.”
If counter is not reset
before reaching “99.”
Upon the next cycle completion, the display
will begin counting at “01.”
broaster.com Manual #14680 3/99 Rev 5/14