5-6
Confidential
1.3 Details of Maintenance Mode Functions for LCD Models
1.3.1 Initialize EEPROM parameters (function code: 01, 91)
<Function>
This function is to initialize the setting values for operation parameters, user switches, and
worker switches (WSW) registered in the EEPROM. Entering function code 01 initializes most
EEPROM areas. Entering function code 91 initializes only the specified areas as shown in the
table below.
<Operation Procedure>
(1) Press the [ ] or [ ] button in the initial state of maintenance mode to display
"Maintenance 01" (or "Maintenance 91") on the LCD.
(2) Press the [OK] button. "PARAMETER INIT" is displayed on the LCD.
(3) When initializing parameters is completed, the machine returns to the initial state of
maintenance mode.
Function code
01 91
Data item
Printer switch (counter information)
Areas not to be
initialized
Areas not to be
initialized
Error history
MAC address
Password for control panel operation lock
Areas to be
initialized
Secure function lock
Worker switches
Areas to be
initialized
User switches
LAN setting
Emulation setting