EasyManuals Logo

BRP Evinrude E-Tec E115DPLSUC User Manual

BRP Evinrude E-Tec E115DPLSUC
443 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #108 background imageLoading...
Page #108 background image
106
ENGINE MANAGEMENT MODULE (EMM)
EMM DIAGNOSTICS
Program Information
Static Information
Refers to information viewed when the outboard is
NOT running. This includes manufacturing infor-
mation.
The outboard model and serial numbers displayed
on the Identity screen must match the identifica-
tion label on the outboard swivel bracket.
The serial number and cylinder location displayed
on the Injector Coefficients screen must indicate
the correct cylinder placement for all injectors.
Dynamic Information
Refers to specific information viewed while the
outboard is running. Dynamic information updates
quickly and allows the viewer to monitor voltage
changes. The displayed information can be used
for troubleshooting and checking outboard infor-
mation.
Service Codes (Faults)
Service codes are fault conditions the EMM has
identified. A service code may be stored as a
result of some unidentified problem or condition. If
no codes are displayed, the engine has no stored
service codes.
Stored Faults
A stored service code represents a previous event
or condition. Service codes are stored if they
occur while the outboard is running.
The Stored Faults screen of the diagnostic pro-
gram shows the code number, the number of
Identity Screen 005399
Injector Coefficients Screen 005142
Engine Monitor Screen 005141

Table of Contents