Step
Procedure
3
Engine test run. See chap. 12-20-00 section: Test run of engine.
4
Inspect the oil filter once more.
Contaminated
ATTENTION
If the oil circuit is contaminated, replace the oil cooler and flush the oil circuit.
See chapter 12–20–00 section: Flushing the oil circuit. Proper judgement re-
quires years of experience in repair of piston engines.
12–20–00
Page 46
January 01 2020
Effectivity: 912 Series
Rev. 0