EasyManua.ls Logo

BRP ROTAX 912 Series - Non Compliance with the Coolant Specification

BRP ROTAX 912 Series
177 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
BRP-Rotax
MAINTENANCE MANUAL LINE
NON COMPLIANCE WITH THE COOLANT SPECIFICATION
General note
ATTENTION
Use only coolant as recommended in the current Operators Manual
Non compliance with the coolant specification
Step
Procedure
1
When a different coolant than the former one (conventional coolant) used,
then the coolant system has to be flushed.
See Chapter 12-20-00 section Flushing the cooling system.
2
Fill expansion tank with new coolant (highest point of the coolant system).
See Chapter 12-10-00 section Coolant check/replenish.
3 Re-install the radiator cap.
4
NOTE
Run engine for a minute and replenish as required.
05–50–00
Page 24
January 01 2020
Effectivity: 912 Series