MAINTENANCE MANUAL LINE
OIL SPECIFICATION NOT RESPECTED
General note
NOTE
An entry by the pilot in the engine log book of all pertinent details is required.
If by error engine was serviced with oil, which does not correspond with oil specification in
the Operators Manual and the engine has been in operation for less than 5 hours, the fol-
lowing measures must be taken:
Less than 5 hr.
Oil specification not respected
Step
Procedure
1 Oil change.
2
Remove the lowest positioned banjo screw (1) (banjo bolt, plug screw or
screw socket) and drain the remaining oil from the crankcase. Re–install in
banjo bolt or plug screw.
Tightening torque see Installation Manual for the engine type
912 Series.
3 Replace oil filter.
4
Drain oil completely from oil cooler and oil hoses.
5
Drain oil from oil tank.
6 Refill oil tank with oil as specified, refer to Operators Manual.
7
Purge air from oil system.
See Chapter 12-20-00 section Purging the oil system.
8 Run engine for approx. 1 hour and change oil and oil filter once more, see
Chapter 12–20–00 section Oil change.
Effectivity: 912 Series
Rev. 0
05–50–00
Page 29
January 01 2020

Table of Contents

Other manuals for BRP ROTAX 912 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the BRP ROTAX 912 Series and is the answer not in the manual?

BRP ROTAX 912 Series Specifications

General IconGeneral
BrandBRP
ModelROTAX 912 Series
CategoryEngine
LanguageEnglish

Related product manuals