EasyManuals Logo

BRP ROTAX 912 Series User Manual

BRP ROTAX 912 Series
177 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #146 background imageLoading...
Page #146 background image
BRP-Rotax
MAINTENANCE MANUAL LINE
CHECKING OF THE FLOAT CHAMBER
General note
m WARNING
Danger of severe burns and scalds! Always allow the engine to cool down to am-
bient temperature before starting any work.
Instruction To check of the float chamber the following steps are necessary. See Figure: Float
chamber.
Step
Procedure
1
Remove drip tray (1).
2 Open spring clip (2).
3
Remove float chamber (3) with gasket (4) and both floats.
4
Remove both floats (5) from the float chamber.
5
Accomplishment of section “Check of weight of the floats.”
6
Inspect the float chamber for contamination and corrosion.
ATTENTION
If any contamination on float chamber the find out what the cause is and take cor-
responding action to rectify the problem. Inspect and clean the complete fuel
system including carburetor.
Step
Procedure
7
Assembly at the float chamber should be carried out in reverse of steps 3.
8
Adjust with the idle speed adjustment. See Chapter 12-20-00 section Idle
speed adjustment.
12–20–00
Page 34
January 01 2020
Effectivity: 912 Series
Rev. 0

Table of Contents

Other manuals for BRP ROTAX 912 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the BRP ROTAX 912 Series and is the answer not in the manual?

BRP ROTAX 912 Series Specifications

General IconGeneral
BrandBRP
ModelROTAX 912 Series
CategoryEngine
LanguageEnglish

Related product manuals