MAINTENANCE MANUAL LINE
CHECKING OF THE FLOAT CHAMBER
General note
m WARNING
Danger of severe burns and scalds! Always allow the engine to cool down to am-
bient temperature before starting any work.
Instruction To check of the float chamber the following steps are necessary. See Figure: Float
chamber.
Step
Procedure
1
Remove drip tray (1).
2 Open spring clip (2).
3
Remove float chamber (3) with gasket (4) and both floats.
4
Remove both floats (5) from the float chamber.
5
Accomplishment of section “Check of weight of the floats.”
6
Inspect the float chamber for contamination and corrosion.
ATTENTION
If any contamination on float chamber the find out what the cause is and take cor-
responding action to rectify the problem. Inspect and clean the complete fuel
system including carburetor.
Step
Procedure
7
Assembly at the float chamber should be carried out in reverse of steps 3.
8
Adjust with the idle speed adjustment. See Chapter 12-20-00 section Idle
speed adjustment.
12–20–00
Page 34
January 01 2020
Effectivity: 912 Series
Rev. 0