BRP-Rotax
MAINTENANCE MANUAL LINE
Points of Inspection
Interval Operating hours Chapter
Reference
Signa-
ture
* no periodic maintenance (re-
quirement after the first 25 hours
of operation)
25* 50 100 200 400 600 1000
3) Spark plug
Check that resistance spark plug
connectors fit tightly on the spark
plugs. Minimum pull-off force is 30 N
(7 lb).
X 12–20–00
Inspection
of spark
plugs
Remove all spark plugs and check
for spark plug defects (deposits, ex-
cessive wear melting....)
Replace if defective.
Check if GENUINE ROTAX® spark
plugs are used.
X X 12–20–00
Remove the
spark plugs
Replacing spark plugs.
(3
use of leaded fuel more than 30%
of operation
X
(3
X 12–20–00
Installation
of spark
plug
4) Inspecting the magnetic plug
Check the magnetic plug.
X X 12–20–00
Inspecting
the mag-
netic plug
5) Inspecting the oil filter
Remove old oil filter from engine.
Cut old filter without producing any
metal chips and inspect following
components for wear and /or missing
material.
Perform filter mat inspection:
Findings.
__________________________
X
X
(4
X
12–20–00
Inspection
of the oil fil-
ter compo-
nents
(4
use of leaded fuel more than 30% of operation
6) Visual inspection of the engine
General visual inspection of the en-
gine for damage or abnormalities.
Check cooling air duct and cooling
fins of the cylinders for obstruction,
cracks, wear and good condition.
X X 12–20–00
Visual
inspection
05–20–00
Page 10
January 01 2020
Effectivity: 912 Series
Rev. 0