EasyManuals Logo

BRP ROTAX 912 Series User Manual

BRP ROTAX 912 Series
177 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #86 background imageLoading...
Page #86 background image
BRP-Rotax
MAINTENANCE MANUAL LINE
Exceeding of max. coolant temperature
All engines affected with serial number with Suffix –01.
General note See SB-912-068, latest issue.
ATTENTION
If the maximum coolant temperature is exceeded, other limits are also often ex-
ceeded, e.g. oil temperature. Please observe the relevant instructions.
NOTE
Any exceeding of the max. admissible coolant temperature must be entered by
the pilot into the engine log book, stating duration, extent of excess temperature
and pertinent detail.
Proceed as instructed
in table 2
Proceed as instructed
in table 1
Operating limit
(See Operators Manual 912 Series)
135 °C
(275 °F)
0
30 min. Time
Figure 5.13: Overview and proceed:
05–50–00
Page 22
January 01 2020
Effectivity: 912 Series
Rev.

Table of Contents