EV100 Handset Operation
PS S5.5 5710
F-code Section C-code
Version no T-code
000
© BT Products AB
233
Service Manual 1997-09-15
6. Function Numbers for Controllers
IC3645EVLXCD1TT
IC3645EVLXCD1TX
6.1. Function 1
Stored Fault Code (Push 1)
This function register contains the last fault that shut down
truck operation (PMT type fault that is reset by cycling the key
switch). This fault code will be over written each time a new
fault occurs and be cleared from memory by adjusting the
value to zero.
6.2. Function 2
Creep Speed (Push 2)
This function allows for the adjustment of the creep speed of
the truck. A constant creep speed frequency will be
maintained when an accelerator input voltage between 3.7
and 3.5 volts or an accelerator ohmic input between 6K and
4.7K ohms is provided.
Range 5% to 15% on time
Set 0 to 255
Resolution .03% per set unit
Example: Setting of 20 = 5.6% on time
6.3. Function 3
Controlled Acceleration and 1A Time (Push 3)
This function allows for the adjustment of the rate of time it
takes for the control to accelerate to 96 percent applied
battery voltage to the motor on hard acceleration. The 1A
contactor will automatically close 0.2 seconds after the
controlled acceleration stops and the accelerator input is less
then 0.5 volts or less then 50 ohms.
Range 0.1 to 22.0 seconds
Set 0 to 255
Resolution 0.084 seconds per set unit
Example: Setting of 20 = 1.8 seconds C/A
and 2.0 1A time.