Battery Controller / Hourmeter / Lift Interrupt
PS S5.3 5230
F-code Section C-code
Version no T-code
001
© BT Products
149
Service Manual 1997-04-15
Battery Controller / Hourmeter /
Lift Interrupt
1. General Information
This instrument consists of a single, quartz hourmeter (H), a
10 bar multicolored battery discharge controller (BC), and a
lockout relay. The lift lockout relay is operated so that if there
is a current passing through the relay contacts when the
instrument registers empty battery the contacts stay closed
until the current ceases. There will be no lockout of the lift
during the lift operation. The hourmeter features a liquid
crystal display (LCD) which has six segment digits with a
decimal point before the last digit. This provides resolution of
0.1 hours or 6 minutes.
2. Electrical
2.1. Voltage
This instrument is supplied as a pin selectable dual voltage
unit with the voltage of 12/48 VDC.
Battery Display LED
2 Red, 3 Yellow, 5 Green