5.3 Quick commissioning (Quick operation menu)
z Press to open the quick operation menu.
SHORTCUT\ Menu item
Input range
Factory setting in
bold
Other information
BASIC SETUP Which language
should be used?
German ...
HYDR. SEP. Have you installed a
module for the
hydraulic separator?
Yes, No
1)
PLANT Is heating circuit 1
installed (unmixed
heating circuit)?
Yes, No
NO. OF MIXERS How many mixed
heating circuits are
installed?
0
0 to 3
Set the address on the rotary
encoder on the mixer module
(factory setting: HC2).
1)
HTG. CIRC. 1
(and other heating
circuits)
Which operating unit
is assigned to heat-
ing circuit 1?
RC20/RC20RF,
RC35
None
To assign programming units
to heating circuits, see
page 30.
For general heating circuit
data, see page 26.
Set any other heating circuits
in the same way as for heat-
ing circuit 1.
How should heating
circuit 1 be control-
led?
Outside temp. con-
trolled,
room temp. controlled
Which heating sys-
tem does heating
circuit 1 have?
Radiator, convector,
floor
For heating characteristics,
see page 31
Table 7 Quick operation menu navigator
SERVICE MENU
B
quick operation
settings
diagnosis
servicing