Entering system settings (Service menu – Settings)
6
RC35 programming unit - Technical specifications are subject to change without prior notice.
22
6 Entering system settings (Service menu – Settings)
6.1 System data
z Press the buttons + + at the same time to open
the SERVICE MENU.
z Turn the rotary selector anti-clockwise until Settings is
selected (marked with ).
z Press to open the SERVICE \ SETTINGS menu.
Note that the menu items shown will vary depending on the heating system.
z Press to select plant data.
The menu SETTINGS \ SYSTEM is opened.
Menu item
Input range
Factory setting in bold
Other information
Which language should
be used?
German, ...
Have you installed a
module for the hydraulic
separator?
Yes, No
1)
Is heating circuit 1
installed (unmixed heat-
ing circuit)?
Yes, No
How many mixed heat-
ing circuits are installed?
0
0 to 3
Set the address on the rotary
encoder on the mixer module (fac-
tory setting: HC2).
1)
Have you installed a
solar module?
Yes, No
1)
Should the outside temp.
delay be switched off?
Yes, No If Yes, the following parameter
(building type) is not shown.
Table 8 Navigator for Service menu SETTINGS \ SYSTEM