Commissioning
5
RC35 programming unit - Technical specifications are subject to change without prior notice.
20
5.4 Detailed commissioning
z Check whether the factory settings in Service menu \ Settings are suitable for the
customer's heating system.
z Note down modified settings if needed.
5.5 System handover
z Make sure that both dials on the BC10 boiler controller
1
are set to “Aut”, so that DHW
temperature and flow temperature are controlled by the RC35 programming unit.
z Explain to the customer how the device works and how to operate it.
z Inform the customer of the settings chosen (using the Setup log at the end of the oper-
ating instructions manual).
DHW Have you installed
domestic hot water?
Yes, No
Which heating circuit
should be used for
domestic hot water?
3-way switching
valve
Cylinder charge pump
Always set to 3-way switch-
ing valve in the case of boilers
with DBA.
To which tempera-
ture should your
domestic hot water
be heated?
60°C
30 to 80°C
To allow the hot water tem-
perature to be changed, set
the hot water dial on the
boiler controller to Aut.
SOLAR MODULE Have you installed a
solar module?
Yes, No
1)
1) Not possible or not available for boilers with UBA1.x and DBA.
Use the checklist on page 18 to check whether more settings are needed.
1) On boilers with UBA1.x and DBA there is no BC10. See the technical documentation for the boiler
for information on its mode of operation.
We recommend giving these installation and servicing instructions to the cus-
tomer so they can be kept close to the heating system.
SHORTCUT\ Menu item
Input range
Factory setting in
bold Other information
Table 7 Quick operation menu navigator