EasyManua.ls Logo

Buell 2007 FIREBOLT - Trouble Code 44

Buell 2007 FIREBOLT
631 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
4-84 2007 Buell Firebolt: Fuel System
HOME
TROUBLE CODE 44 4.27
GENERAL
NOTE
See Figure 4-59. When vehicle lean angle causes weighted
pendulum to enter shaded area for a period of greater than
one second, ECM shuts off ignition and fuel systems.
Bank Angle Sensor
See Figure 4-60. A Code 44 occurs when the bank angle
sensor (1) voltage is outside the normal operating range of
0.24-4.79 volts. This may be caused by:
Short to ground in harness between sensor and elec-
tronic control module.
Short to voltage in harness between sensor and elec-
tronic control module.
Failed sensor.
If this code occurs, the engine will continue to run and can be
ridden to the dealership for repair.
DIAGNOSTICS
Diagnostic Notes
The reference numbers below correlate with the circled num-
bers on the Code 44 flow charts.
1. Use HARNESS CONNECTOR TEST KIT (Part No. HD-
41404), gray pin probes and patch cord.
2. Connect BREAKOUT BOX (Part No. HD-42682) to ECM.
See 4.6 BREAKOUT BOX.
Figure 4-59. Bank Angle Sensor Operation
Figure 4-60. Bank Angle Sensor
Table 4-31. Bank Angle Sensor Voltage
MODE VOLTS
Run 0.24-3.4
Disable 3.5-4.79
b1085x4x
Run Mode 0.24-3.4 volts
Disable Mode 3.5-4.79 volts
Weighted pendulum
8428
1. Bank angle sensor
2. Headlights
1
2

Table of Contents