EasyManua.ls Logo

Buffalo LinkStation 210D - Chapter 5 Remote Access; WebAccess; Configuring from Easy Admin

Buffalo LinkStation 210D
137 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
56
Chapter 4 Storage Management
Using RAID 1
1 From Advanced Settings, navigate to [Drives] > [RAID].
2 Click the RAID array that held the failed drive.
3 Select the replaced drive and click [Recover RAID Array].
4 Enter the confirmation number, then click [OK].
Using RAID 0
1 From Advanced Settings, navigate to [Drives] > [RAID].
2 Click the RAID array that held the failed drive and click [Delete RAID Array].
3 The “Confirm Operation” screen will open. Enter the confirmation number, then click [OK].
4 From [Drives] > [Drives], select the replaced drive and click [Format Disk].
5 The “Confirm Operation” screen will open. Enter the confirmation number, then click [OK].
6 From [Drives] > [RAID], choose “RAID 0” from the RAID mode drop-down list and click [Create RAID Array].
7 The “Confirm Operation” screen will open. Enter the confirmation number, then click [OK].
8 Click [OK] when completed.
The new RAID 0 array will be created. Next, create a shared folder by referring to the “Adding a Shared Folder”
section in chapter 3.
Using JBOD
1 From Advanced Settings, navigate to [Drives] > [Drives].
2 Select the replaced drive and click [Format Disk].
3 The “Confirm Operation” screen will open. Enter the confirmation number, then click [OK].
The drive will be formatted. Next, create a shared folder by referring to the “Adding a Shared Folder” section in
chapter 3.

Table of Contents