Engine Shutdown
Allow the engine to run at low idle, in neutral, for a few minutes after operations are completed. In this way after-
boiling is avoided at the same time as temperature equalization takes place. This is especially important when
the engine has been run at high rpm or under heavy load.
Stop the Engine
IMPORTANT:
Never disconnect the current using the main switches
when the engine is running.
The alternator and electronics could be damaged.
IMPORTANT:
Make sure the ignition is turned off before the main
switches
are switched off. Otherwise the alternator and
electronics could be damaged.
Stopping Using the Start/Stop Panel
1 Disengage the drive/reverse gear by putting the
control lever in neutral.
2 Stop the engine(s) by pushing the START/STOP
button(s).
Stopping Using the e-Key
IGNITION IGNITION
START/STOP
START/STOP
P0016518
1 Disengage
the drive/reverse gear by putting the
control lever in neutral.
2 Push the stop button(s). Release the button(s)
when the engine(s) has/have stopped.
Turn the ignition off and lock the EVC system
To turn the ignition of, press the IGNITION button.
The green lamp in the IGNITION button goes out to
indicate the ignition is off.
To lock the EVC system, hold the key fob in front of
the symbol on the e-Key panel.
A flashing red light indicates the system is locked.
47708085 11-2016 © Bukh 63