Emergency Stop Switch
Reset the external stop button.
Battery Voltage
Possible cause: The alternator output voltage is too low.
Corrective action: • Check the battery. Refer to Battery, page 105.
•
Check belt tension. Refer to Drive Belt, Check and Change, page 92.
Can Not Start, Trim Too High
Possible cause: • The drive is tilted too high.
• Trim sender failure.
Corrective action: It is possible to override the immobilizer by pressing the start button for 5 seconds and
then stop pressing the button.
Check Control Lever
Possible cause: • Shift and throttle incorrect.
•
Slip function not available.
Corrective action: Acknowledge the fault by moving the control to Neutral and press the OK button. Engine power
is reduced and the gear is automatically set to Neutral.
Check Engine
Possible
cause:
• Battery voltage is incorrect.
•
The fuel pressure is incorrect. Engine performance might be affected.
• Communication failure automatically sets the gear to Neutral. Engine performance might
be affected.
• The oil pressure is too low and the engine power is reduced.
Corrective
action:
• Check the battery. Refer to Battery, page 105.
• Check the oil level and that there is no leakage. Refer to Oil level, checking and topping
up, page 94.
Check EVC System
Possible cause: • Limited or no steering.
•
Shift and throttle are unavailable and the gear has automatically been set to Neutral as
engine power is reduced and the helm station has lost communication with the engine.
• Control panel failure.
Corrective
action:
• Use alternative helm station if possible.
• Check if any buttons are stuck.
Fault Code Register
72 47708085 11-2016 © Bukh