  • J
    Jennifer Johnson DDSSep 1, 2025
    What to do if my Bürkert Transmitter shows 'PWR FAIL'?
    • S
      Sandra WilliamsSep 1, 2025
      If the Bürkert Transmitter displays 'PWR FAIL', it indicates that the supply voltage is too low. This could be because the voltage at the device terminals is below 12 V or the impedance of the current measurement loop is too high. To resolve this, adjust the supply voltage to ensure the voltage at the device terminals is between 12 V and 36 V.
  • E
    Ellen RobersonSep 12, 2025
    What does 'W. BATCH' mean on my Burkert SE35?
    • W
      William JamesSep 12, 2025
      If the device state LED on your Burkert Controller is orange and displays the message 'W. BATCH', it means the number of completed dosings has reached the value specified in the 'BATCH-W.' parameter of the Test menu. To address this, perform the planned maintenance operation and reset the daily totalizer of the completed dosings.
  • K
    Kelly TaylorAug 30, 2025
    Why is the displayed flow rate always nil on my Bürkert Measuring Instruments?
    • J
      jeffrey63Aug 30, 2025
      If the displayed flow rate on your Bürkert Measuring Instruments is always nil, ensure the flow rate in the pipe is not nil, check that the entered K factor is correct. Also, consider choosing a smaller flow rate unit or increasing the number of displayed decimals.
  • A
    allenalexandraSep 14, 2025
    What does 'ERROR3' mean on my Burkert SE35 Controller and how do I fix it?
    • M
      Mary MooreSep 14, 2025
      If the device state LED on your Burkert Controller is red with the message 'ERROR3', it signifies that the user parameters have been lost. Try restarting the device. If the message persists, reconfigure the device.
  • V
    Victoria SmithSep 13, 2025
    What does 'CONTINUE' mean on my Burkert SE35?
    • J
      Jill HodgeSep 13, 2025
      If the device state LED on your Burkert Controller is any colour and displays the message 'CONTINUE', it indicates that the power supply was interrupted during a dosing, causing the dosing to be interrupted. Check the electrical installation. You can either abort the current dosing or continue it, but in the latter case, verify that the current dosing is accurate.
  • M
    Melissa VillaSep 18, 2025
    Why is the displayed quantity increasing slowly on my Burkert SE35 Controller during dosing?
    • S
      Susan PattersonSep 18, 2025
      If, during a dosing process, the displayed quantity on your Burkert Controller increases or decreases very slowly and the device state LED is green, check that the K-factor corresponds to the fitting used. You may also perform a Teach-In procedure to determine the K-factor of the fitting used and check that the flow rate in the pipe is high enough.
  • M
    Marcus ParkerSep 23, 2025
    What does 'Process level' mean on my Burkert SE35?
    • L
      Lori SchmidtSep 23, 2025
      If your Burkert Controller's device state LED displays any colour with the message 'Process level', it indicates that the power supply was cut during the consultation of the messages of the Information menu via the digital inputs. Ensure that the PLC recognizes that the device has returned to the Process level.
  • J
    Jennifer WalkerAug 27, 2025
    What does 'ERROR4' mean on Bürkert Measuring Instruments and how to fix it?
    • A
      alejandraorozcoAug 27, 2025
      If your Bürkert Measuring Instruments displays 'ERROR4', it means the totalizer values are lost, and the values saved upon the next to last power down are retrieved. Try restarting the device.
  • T
    Taylor LewisAug 26, 2025
    What does 'ERROR3' mean on Bürkert Measuring Instruments and how to fix it?
    • J
      Julie MorganAug 26, 2025
      If your Bürkert Measuring Instruments displays 'ERROR3', it means the user settings are lost, and the device might measure incorrect values. Try restarting the device. If the message continues, reconfigure the device.
  • E
    Edwin RyanAug 25, 2025
    What does "MEAS. OVF" mean on Bürkert Measuring Instruments and how to fix it?
    • C
      Christine BuckleyAug 26, 2025
      If the Bürkert Measuring Instruments shows 'MEAS. OVF', the rotational frequency of the paddle wheel is higher than 250 Hz. Check and adjust the flow rate in the pipe if necessary.

Summary

Intended Use

Basic Safety Information

Technical Data

Technical Data: 8025 Batch Compact Version

Lists environmental, electrical, and fluid specifications for the compact model.

Technical Data: 8025 Batch Panel Version

Lists environmental, electrical, and fluid specifications for the panel model.

Technical Data: 8025 Batch Wall-Mounted Version

Lists environmental, electrical, and fluid specifications for the wall-mounted model.

Technical Data: SE35 Batch

Lists environmental, electrical, and fluid specifications for the SE35 Batch.

Technical Data: 8035 Batch

Lists environmental, electrical, and fluid specifications for the 8035 Batch.

Technical Data: SE35 Batch with S070;S077

Lists technical specs for SE35 Batch with specific sensor-fittings.

Fluid Installation

Fluid Installation Safety Instructions

Crucial safety guidelines for the fluid installation process.

Installing 8025 Batch in Compact Version

Step-by-step instructions for installing the 8025 Batch in its compact form.

Installing 8035 Batch

Step-by-step instructions for installing the 8035 Batch.

Electrical Installation and Wiring

Electrical Installation Safety Instructions

Critical safety measures for electrical connections and wiring.

Commissioning

Commissioning Safety Instructions

Safety precautions to follow before and during device commissioning.

Commissioning Procedure

Step-by-step guide for bringing the device into operation.

Operating and Functions

Operating Safety Instructions

Critical safety measures for operating the device correctly.

Parameters Menu Details

Covers configurable parameters like language, units, K-factor, outputs, and alarms.

Maintenance and Troubleshooting

Maintenance Safety Instructions

Critical safety measures for performing maintenance tasks.

Troubleshooting Problems

Guides users through resolving issues based on LED status, error messages, and warnings.

Spare Parts and Accessories

Burkert SE35 Specifications

General IconGeneral
BrandBurkert
ModelSE35
CategoryController
LanguageEnglish

Related product manuals