12 - Manual FA01869-EN - 08/2022 - © CAME S.p.A. - The contents of this manual may be changed, at any time, and without notice. - Translation of the original instructions
Main control unit components
PXC2-32 / PXC2-64 PXC2-212
❶ 230 Vac mains connection terminals. Be careful, live parts
❷ Earth Faston / Terminal connection
❸ Earth connection cable for cover
❹ Battery-connection cables. Respect the polarity (red = +, black = -)
❺ Control unit tamper
The battery must be secured to the control unit mechanics using double-sided tape.
- use a VRLA (valve regulated lead acid) battery
- the battery casing must be flammability standard UL94V-1 or higher
- the battery must comply with standard IEC 60896-21:2004 and/or IEC 60896-22:2004.
- the battery must be replaced by an experienced technician.
In the PXC2-212 control unit, the battery must be installed with the fuse holder supplied and a 6 Ah fuse.
LIST OF ELECTRICAL AND MECHANICAL CHARACTERISTICS
CONTROL UNIT MODEL PXC2-64 PXC2-212
Input power supply voltage 230 V AC; 50-60Hz
Output rated voltage 13.8 V DC
Battery charger voltage (type A – EN50131-6)
13.8 V DC
0.75 A
13.8 V DC
1.1 A
13.8 V DC
1.5 A
Output voltage range 9-14.0 V DC
Overcurrent protection 17.5 V DC
Maximum current draw 0.42 A @ 230 V AC 0.56 A @ 230 V AC 0.85 A @ 230 V AC
Control board current draw 150 mA 150 mA 150 mA
Low SD level (battery) 11.4 V 11.4 V 11.4 V
Power supply outputs fault voltage 9.8 V 9.8 V 9.8 V
Intervention voltage for SD deep discharge protection 9.5 V 9.5 V 9.5 V
Maximum ripple on the output power supply voltage 200 mV 200 mV 200 mV
Alarm transmission operating mode Pass-through
Operating temperature - 10 to + 40 °C
Maximum humidity (not condensed) 75%
IP protection rating 30
ATS classification [EN50131] SP3
Casing size (mm) 405x295x90 490x360x90
Safety rating EN50131-3 2 2 3
Safety rating EN50131-6 2 2 3
Environmental class II II II
Maximum degree of pollution 2 2 2
Compliant with EN60950-1, EN50130-4-1, EN50131-1, EN50136-2
IMQ certification