#
RX TX
%
#
28
48
Pag.
13 -
Manual code
:
119ES 87 ver.
2 01/2013
© CAME cancelli automatici s.p.a. -
The data and information reported in this installation manual are susceptible to change at any time and without obligation on CAME cancelli automatici s.p.a. to notify users.
ENGLISH
N.C. Contact for “reopening during closing”
- Input for photocells, sensitive profi les and other devices
complying with EN 12978 standards.
During the closing phase, operating the device will invert the
motion until complete opening is achieved.
Key and/or push button selector switch (N.O. contact) - Opening and closing
devices.
Command modes: open-stop-close-stop, open-close and open only.
Stop button (N.C. contact) - Stops movement, excludes the automatic closing
functions. To restart the automated kit, press a command button or a remote control
button.
Key and/or button selector (N.O. contact) to open the door.
If a button is connected, then
remove the fuse-bridge.
Command and safety devices