27
Models C708/C709/C716/C717
Controls, Systems and Operations
H: 40.9 B:26.3 L
HEAT OVER COOL PEAK
1:12 0:49 h 1:19 161.0
0:46 1:11 b 0:15 169.7
H: 38.0 B:23.7 R
HEAT OVER COOL PEAK
1:09 0:52 h 1:11 161.2
0:66 1:00 b 0:11 169.9
The HEAT time indicates the amount of time taken
in each zone to reach 150.9°F (66.1°C). Each zone
must remain above 150°F (65.6°C) for a minimum of
35 minutes.
Touch the UP arrow symbol to advance to the next
page or the DOWN arrow symbol to view the
previous page. A Heat Cycle Failure message will
display on the first screen if a failure occurred.
Listed below are variable failure code messages
which could appear on line 2.
HT HEAT TIME FAILURE
Mix temperature did not rise above 151_F
(66.1_C) in less than 90 minutes.
CL COOL MODE FAILURE
Mix temperature in the hopper and freezing
cylinder did not fall below 41_F(5_C) in less
than 90 minutes.
TT TOTAL TIME FAILURE
The heat treatment cycle must be completed
in no more than 4 hours.
ML MIX LOW FAILURE
The Heat Phase or Cool Phase time was
exceeded and a mix low condition was
present.
MO MIX OUT FAILURE
A mix out condition was detected at the start
or during the heat cycle.
BO BEATER OLVD IN HC
A beater overload occurred during the heat
cycle.
HO HPCO IN HEAT CYCLE
A high pressure cut-out condition occurred
during the heat cycle.
PF POWER FAILURE IN HC
A power failure caused the Heat Phase,
Cool Phase, or Total Cycle Time to exceed
the maximum allowed time. If a power failure
occurs, but the heat treatment cycle does
not fail, an asterisk(*) will appear on the third
line of the display.
OP OPERATOR INTERRUPT
Indicates the heat cycle was aborted in the
OPERATOR INTERRUPT option in the
Service Menu.
PS POWER SWITCH OFF
The power switch was placed into the OFF
position during the heat cycle.
TH THERMISTOR FAILURE
A thermistor probe has failed.
PD PRODUCT DOOR OFF
A product door is not in place or is loose.
System Information
The SYSTEM INFORMATION is displayed on three
separate screens. The first screen contains the
control and software version installed in the
machine.
SOFTWARE VERSION
C708 CONTROL UVC3
VERSION 1.06
> Next
Touch the SEL symbol to advance to the next
system information screen containing the software
language version.
Language
V2.00 English 621
> Next
Touch the SEL symbol to advance to the third
system information screen containing the model bill
of material and machine serial number. Touching the
SEL symbol again will return to the Menu list.
B.O.M. C70827C000
S/N K0000000
> Next