28
Controls, Systems and Operations
Models C708/C709/C716/C717
060821
Current Conditions
The CURRENT CONDITIONS screen provides the
viscosity readings for the product when the machine
is running, and the hopper and the freezing cylinder
temperatures for the machine.
VISC 0.0
HOPPER 41.0
CURRENT CONDITIONS is the only Menu screen
that will return the control panel keys to normal
operation. The Menu symbols will not be lit when
this option is selected but the panel touch keys are
fully functional. Exit the CURRENT CONDITIONS
screen and return to the Menu by touching the SEL
symbol.
Service Menu
______________________________
The Service Menu option allows trained service
technicians to access and modify critical operating
parameters for the machine. The access code for
the service menu is:
5231.
Service Menu Options
The Service Menu screen includes the following
options which are also displayed in the Manager
Menu. (See page 20.)
EXIT FROM MENU
RESET DRAW COUNTER
SET CLOCK
AUTO HEAT TIME
AUTO START TIME
STANDBY MODE
BRUSH CLEAN CYCLE
MIX LEVEL AUDIBLE
FAULT DESCRIPTION
LOCKOUT HISTORY
HEAT CYCLE SUMMARY
HEAT CYCLE DATA
SYSTEM INFORMATION
CURRENT CONDITIONS
The Service Menu screen also includes the following
options which can only be accessed through the
Service Menu:
TEMPERATURE SCALE
STANDBY TEMP
HOPPER TEMP
HEAT TREAT TEMPS
VISCOSITY SET TING
COMPRESSOR CYCLE TIME
COMPRESSOR ON DELAY
BEATER OFF DELAY
MIXPUMPOFFDELAY
EDIT UNIT ID
SELECT LANGUAGE
ABORT HEAT CYCLE
MANUAL CONTROL
RESET TO DEFAULTS
Temperature Scale
This option allows the service technician to choose
the scale in which the machine will display all
temperatures.
TEMPERATURE SCALE
FAHRENHEIT
>FAHRENHEIT
CELSIUS
Pressing the UP key moves the arrow to Fahrenheit.
Pressing the DOWN key will move the arrow to
Celsius. Pressing the SEL symbol with the arrow
next to the appropriate option will select this option
and return to the Service Menu screen.
Standby Temp
This option allows the technician to adjust the
freezing cylinder temperature at which the
compressor will turn on in STANDBY. The Standby
Temp screen is displayed upon selecting this option.
STANDBY TEMP
CUT IN AT : 39.0
CURRENT : 39.0
> Next