35
Models C708/C709/C716/C717
Controls, Systems and Operations
Freezer Lock-Out
To comply with health codes, heat treatment system
freezers must complete a heat treatment cycle
daily, and must be disassembled and brush cleaned
a minimum of every 14 days. Brush cleaning is the
normal disassembly and cleaning procedure found in
the Operator Manual. Failure to follow these
guidelines will cause the control to lock the freezer
out of the AUTO mode.
If the Heat Treatment Cycle fails, the screen will
display a failure message and return the freezer to
the STANDBY mode.
Always comply with local guidelines for the
maximum number of days allowed between brush
clean cycles. (See the Manager’s Menu for setting
the Brush Clean interval.)
There are two types of freezer lock conditions that
can occur: Hard Lock or Soft Lock. A Hard Lock
requires the machine be disassembled and brush
cleaned. A Soft Lock can be corrected by either
disassembling and brush cleaning the machine, or
by starting another heat treatment cycle.
Hardlock
There are two causes of a hard lock failure. The
freezer will hardlock if either the Brush Clean Timer
has elapsed or if a Thermistor Failure (Freezing
Cylinder or Hopper) occurred during a Heat cycle.
1. The following screen will be displayed if a Brush
Clean Cycle Time has occurred.
BRUSH CLEAN TIMEOUT
FREEZER LOCKED
CLEANING REQ’D
> BRUSH CLEAN
Touching the SEL symbol will display the following
screen.
FREEZER LOCKED
2. The following screen will display if there has
been a thermistor failure (freezing cylinder or
hopper) during the heat treatment process.
SYSTEM FAULT
FREEZER LOCKED
SERVICE REQ’D
> BRUSH CLEAN
Touching the SEL symbol will indicate which
thermistor caused the Hard Lock.
HOPPER THERM BAD
FREEZER LOCKED