31
Models C708/C709/C716/C717
Controls, Systems and Operations
Mix Pump Off Delay ( C708 & C716 Only)
This option allows the technician to set the amount
of time that the mix pump runs after the draw valve
has closed (switch opened). The following screen is
displayed upon entering this option.
MIXPUMPOFFDELAY
RUN TIME : 10 SEC
+ + + -- -- -- S E L
Pressing the UP or DOWN key increases or
decreases the time DELAY by one second
respectively. Pressing the SEL symbol accepts the
setting and returns to the Service Menu screen.
Edit Unit ID
This option allows the technician to enter the factory
Bill of Materials (BOM) code used to assemble the
freezer, the freezer Serial Number, and the Store ID
number. The Freezer BOM screen is displayed first.
ENTER FREEZER BOM
C70833C000
--
Pressing the SEL symbol scrolls the cursor to the
right one place for each symbol press. Pressing the
UP or DOWN key increase or decrease respectively,
with rollover, the selected digits. Once the correct
freezer BOM has been entered, pressing the SEL
symbol displays the Serial Number screen.
ENTER FREEZER SN
K0000000
--
Repeat the operation as described previously. Once
the correct freezer Serial Number has been entered,
pressing the SEL symbol displays the Store ID
screen.
ENTER STORE ID
00000
_
Repeat the operation as described previously. Once
the correct Store ID has been entered, pressing the
SEL symbol returns to the Service Menu screen.
Select Language
This option allows the technician to select one of
seven languages available. The following screen will
be displayed upon selecting this option.
>ENGLISH
ESPANOL
DANSK
FRANCAIS
Pressing the UP and DOWN keys moves the arrow
to the selection. Pressing the SEL symbol with the
arrow next to one of the seven choices selects that
choice and returns to the Service Menu screen. If no
language is selected, the factory default is English.
Abort Heat Cycle
This option allows the technician to abort a Heat
Cycle. The following screen will be displayed upon
selecting this option ifthemachineisinaHeat
Cycle.
ABORT HEAT CYCLE
Yes
>No
Pressing the UP key moves the arrow to “Yes”.
Pressing the DOWN key moves the arrow to “No”.
Pressing the SEL symbol with the arrow next to
“Yes” will abort the Heat Cycle. Pressing the SEL
symbol with the arrow next to “No” has no effect and
will return to the Service Menu screen.