Models C708/C709/C716/C717
Controls, Systems and Operations
060207
Jumper Pins - UVC3
JUMPER PINS FUNCTION
Jumper installed -- normal applications using refrigerated mix.
JP1
Pins 1 & 2
No jumper installed -- general market configuration using
non--refrigerated mix. Ignores hopper temperature lockout parameters to
allow adding non--refrigerated mix into the hopper.
Pins 3 & 4 No jumper -- Not used (for future development)
P
i
n
s
1
&
2
Domestic configuration -- jumper installed. Hopper temperature not
displayed on screen. Heat symbol symbols are only active when a
lockout condition has occurred. Standby symbols are disabled.
JP2
Pins 1 & 2
International configuration -- no jumper. Hopper temperature is
displayed on screen. Manual heat cycle starts by touching the HEAT
symbol. Standby symbols are functional.
Pins 3 & 4 No jumper -- Not used (for future development)
J
P
3
Pins 1 & 2 Remove jumper to disable audible device located on UVC3 control.
JP3
Pins 3 & 4 No jumper -- Not used (for future development)
Note: The new UVC control board jumper blocks have 4 pins. Jumper on pins 1 & 2 are active. Pins 3 & 4 are
open for future development.
Programming Jumpers
Interface Board
W5
If a jumper is present on the left interface board, the real time clock can be changed in any
mode.
W4
Installing a jumper on the left or right interface board forces the liquid solenoid valves, the hot
gas soleniod valves, and the suction solenoid to be energized on the corresponding side of the
unit. Removing the jumper ends their operation. This is used for reclaiming and evacuation of
the refrigeration system only, or manual cycling of the solenoid valves for service check.
W3
A jumper on the W3 of the left interface board enables the syrup heaters.
W2
If a jumper is present on the left interface board, it resets the brush clean date. If a jumper is
present on the right interface board, it enables the 59°F(15°C) product temperature fault.