30
Controls, Systems and Operations
Models C708/C709/C716/C717
Viscosity Setting
This option allows the service technician to adjust
the viscosity at which the compressor turns off in
AUTO. The first screen is displayed upon entering
this function.
VISCOSITY SETTING
VISC = 2.8 AMPS
Change
>Exit
Pressing the UP key moves the arrow to Change.
Pressing the DOWN key moves the arrow to “Exit”.
Pressing the SEL symbol with the arrow next to
“Exit” has no effect, and returns to the Service Menu
screen. Pressing the SEL symbol with the arrow
next to “Change” displays the second screen.
VISCOSITY SETTING
VISC = 2.8 AMPS
Current = 0.0
Pressing the UP key increases the viscosity setting
by 0.1 amp. Pressing the DOWN key decreases the
viscosity setting by 0.1 amp. Pressing the SEL
symbol accepts the viscosity setting and returns to
the Service Menu screen.
Comp Cycle Time
This option allows the technician to set the
Compressor Cycle Time. The following screen is
displayed upon entering this option.
COMP CYCLE TIME
CYCLE TIME : 10 MIN
Pressing the UP or DOWN key increases or
decreases the cycle time by one minute
respectively. Pressing the SEL symbol accepts the
setting and returns to the Service Menu screen.
Comp On Delay
This option allows the technician to adjust the
Compressor On Delay. The following screen is
displayed upon entering this option.
COMP ON DELAY
TIME : 2 SECONDS
Pressing the UP or DOWN key increases or
decreases the time delay by one second
respectively. Pressing the SEL symbol accepts the
setting and returns to the Service Menu screen.
Note: The minimum setting for Comp On Delay is 2
seconds.
Beater Off Delay
This option allows the technician to set the time the
beater motor continues to run after the compressor
has cycled off. The following screen is displayed
upon entering this option.
BEATER OFF DELAY
TIME : 0 SECONDS
Pressing the UP or DOWN key increases or
decreases the time DELAY by one second
respectively. Pressing the SEL symbol accepts the
setting and returns to the Service Menu screen.