14
You can set scale’s environment as below.
▶ Scale Parameter
Menu Sub-menu Setting Value Description
1. Display
(Menu
code:1871)
Display Discount Info Y/N
The scale shows discount
information.
Show Clerk Nickname Y/N The scale shows clerk’s nickname
PLU Name Align
0: Left alignment
1: Center alignment
2: Right alignment
Set the alignment position of PLU
Enable Scroll msg with PLU Y/N
Setting whether scroll message is
showed up or not when PLU is
called
Touch Calibration Y/N Calibrate the touch screen
2. Printing
(Menu
code:1872)
Label prt w.o rewind(x Key) Y/N
Do not use rewind function when
you use “X” key
Confirm prt report on label
0:Print automatically
1:Need to confirm to
print report and do
not confirm any
more until power
off
2:Need to confirm to
print report and do
not confirm any
more until you exit
program mode
Set confirm method when you print
report in label mode
Print origin for comm. Line
0:Do not print
1:print in Name1
2:print in Name2
3:print in Name3
Print origin in commodity line
Print unit symbol in qty area Y/N Print Qty Symbol in qty area
Print pieces in U. Price area Y/N Print Pieces in unit price area
Print all report within range Y/N Print all report
Swedish auto barcode
0:Not use
1:price Auto Code
2:Weight Auto Code
Selection the way and whether
using Swedish automatic barcode
function
Print pack type
0:Not use
1:alphabet
2:day(Moon, Tue,…)
3:day,year
Setting up the type when packing
date is printed
Print Item when return
0:Do not print
1:Print
Print return list when it returns
Print Label when Label #0
Y:Print default label
form
N:Do not print
Print Total label continuously Y/N Set multiple total label
3. Sale Setup
(Menu
code:1873)
Save unit price change Y/N Save unit price change
Save Type change Y/N Save type change in PLU
Start save mode(start up) Y/N
Save mode is active when you turn
on the scale
PLU clr Aft sale(WT.On Tray) Y/N
PLU is cleared after printing even
though there is an item on the
platter
Print count w.o misc. key Y/N
If you enter count, it is considered
that misc. count condition when