C. Set the DC Power Supply output voltage and CCL current as listed in Table 12-5
based
on the test model. Press LOAD ON/OFF to start the Load and gradually reduce the DC
Power Supply voltage till the DMM (V) shows the minimum operating voltage listed in
Table 12-5 per model. The load current recorded by current shunt = DMM (I)
voltage/current shunt resistance.
Table 12-5
Model
Minimum
Operating Voltage