13
Update
Quick Start
READ A SETUP LABEL
CONFIGURE PARAMETERS
For most of the scanner parameters, only one read is required to set them to new values.
The scanner will respond with two beeps when each parameter is set successfully.
But for a number of special parameters, multiple reads are required to complete the
setting. In this case, the scanner will respond with a short beep to indicate it needs to
read more setup labels. These special parameters may require reading one or more setup
labels, such as
î Numeric labels, say, for keyboard type, inter-character delay, length qualification
î Hexadecimal labels, say, for character strings as prefix, suffix, etc.
î When âBT HIDâ, âUSB HIDâ or âKeyboard Wedgeâ is configured for interface, Key
Type and Key Status will then become applicable. You may decide whether or not to
change key status when âNormal Keyâ is selected for Key Type.
To complete the configuration of these special parameters, it requires reading the
âValidateâ label, and the scanner will respond with two beeps (low-high tone) to indicate
the input values are validated.