EasyManua.ls Logo

CISA eSIGNO - Lock Special Functions

CISA eSIGNO
71 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
ESIGNO_SYSTEM_USER_MANUAL_101.DOCX 25/71
L
LL
LOCK
OCKOCK
OCK
S
SS
SPECIAL
PECIAL PECIAL
PECIAL F
FF
FUNCTIONS
UNCTIONSUNCTIONS
UNCTIONS
A
AA
ACCESS
CCESS CCESS
CCESS T
TT
TARGETS
ARGETSARGETS
ARGETS
H
HH
H
ISTORICAL
ISTORICAL ISTORICAL
ISTORICAL
F
FF
F
UNCTION
UNCTIONUNCTION
UNCTION
If this function has been enabled, each operation made by the card is recorded on its own memory.
Once the memory of the card has been written it is possible to download the list of the operations
with the ESIGNO Mobile in encoder mode.
During the installation of the plant it’s possible to choose two different history recording modalities:
N
NN
Not
ot ot
ot rewritable
rewritablerewritable
rewritable: the card can record up to 30 operations. If the memory of the card is full and you
pass it on the lock, it will give you three red blinks: in this case, you have to download the history of
the card with the ESIGNO Mobile in encoder mode, using the Load Card History menu.
In this case, each time you have access to an online special lock (e.g. the hotel main entrance), it will
upload the history of the card in order not to lose records.
R
RR
Rewritable
ewritableewritable
ewritable: the thirty-first operation will be recorded, but it will overwrite the first record. The same
will happen for the subsequent records.
V
VV
V
ALIDATOR
ALIDATOR ALIDATOR
ALIDATOR
F
FF
F
UNCTION
UNCTIONUNCTION
UNCTION
This function is active only if, during the configuration of the special lock, the validation function has
been enabled.
V
VV
Validation
alidationalidation
alidation is a special function that allows to have further control on the validity of issued cards.
In the moment of issuing guest, staff and operators cards, it is possible to set a validation delay: inside
this period of time, the owner of the card has to pass it on a special door (which has been initialized as
V
VV
Validator
alidatoralidator
alidator), in order to refresh the validity of the card. If the validation time has expired and the card has
not been presented to the special lock, the access rights of the card are not valid anymore: to recover
these rights, the card has to be presented to the validator.
R
RR
R
ECODING
ECODING ECODING
ECODING
F
FF
F
UNCTION
UNCTIONUNCTION
UNCTION
This particular function allows you to change some parameters of staff and user cards (e.g. validity,
access targets) without using the encoder but rather through the reader connected to an online
special lock.
An operator, using the encoder, sends a recoding command to the special lock (e.g. the hotel main
entrance), configured as Validator with the recoding function enabled.
When the staff (or user) card is read by the reader connected to the special lock, the parameters of
the card will change in compliance with the instruction given by the recoding command.
To use the recoding function, it is necessary to enable the validation function during the initialization
of the special lock.