7-5
Cisco Aironet 1100 Series Access Point Installation and Configuration Guide
OL-2851-01
Chapter 7 Configuring Radio Settings
Configuring Radio Transmit Power
Configuring Radio Transmit Power
Beginning in privileged EXEC mode, follow these steps to set the transmit power on your access point
radio:
Use the no form of the power command to return the power setting to maximum, the default setting.
Limiting the Power Level for Associated Client Devices
You can also limit the power level on client devices that associate to the access point. When a client
device associates to the access point, the access point sends the maximum power level setting to the
client.
Beginning in privileged EXEC mode, follow these steps to specify a maximum allowed power setting on
all client devices that associate to the access point:
Use the no form of the client power command to disable the maximum power level for associated clients.
Note Aironet extensions must be enabled to limit the power level on associated client devices. Aironet
extensions are enabled by default.
Command Purpose
Step 1
configure terminal Enter global configuration mode.
Step 2
interface dot11radio 0 Enter interface configuration mode for the radio interface.
Step 3
power local
{ 1 | 5 | 20 | 30 | 50 | 100 | maximum }
Set the transmit power to one of the power levels allowed in
your regulatory domain. All settings are in mW.
Note The settings allowed in your regulatory domain might
differ from the settings listed here.
Step 4
end Return to privileged EXEC mode.
Step 5
copy running-config startup-config (Optional) Save your entries in the configuration file.
Command Purpose
Step 1
configure terminal Enter global configuration mode.
Step 2
interface dot11radio 0 Enter interface configuration mode for the radio interface.
Step 3
power client
{ 1 | 5 | 20 | 30 | 50 | 100 }
Set the maximum power level allowed on client devices that
associate to the access point. All settings are in mW.
Note The settings allowed in your regulatory domain might
differ from the settings listed here.
Step 4
end Return to privileged EXEC mode.
Step 5
copy running-config startup-config (Optional) Save your entries in the configuration file.