au-3 1
mode vc1x
tug-2 1 payload vc11
t1 1 bert pattern 2^11 interval 10
end
Configuring E1 Bert
To configure E1 Bert:
enable
configure terminal
controller MediaType 0/5/0
mode sdh
controller sdh 0/5/0
rate stm4
au-3 1
mode vc1x
tug-2 1 payload vc12
e1 1 bert pattern 2^11 interval 10
end
Configuring BERT in Mode T3/E3
To configure BERT in Mode T3/E3 for both AUG mapping AU-3 and AU-4:
configure terminal
controller sdh 0/4/7
rate STM1
no ais-shut
alarm-report all
clock source internal
overhead s1s0 0
aug mapping au-4
au-4 1
mode tug-3
clock source internal
tug-3 1
mode t3
threshold b3-tca 0
overhead c2 0
t3 clock source internal
t3 bert pattern 2^15 internal 10 direction [line | system]
Verifying BERT Configuration in Mode T3/E3
Use show controllers command to verify BERT configuration in mode T3/E3:
show controller sdh 0/4/7 | sec BERT
BERT test result (running)Test Pattern : 2^15,
Status : Sync, Sync Detected : 0Interval : 10 minute(s),
Time Remain : 00:09:47
Bit Errors (since BERT started): 0 Mbits,
Bits Received (since BERT started): 0 Mbits
Bit Errors (since last sync): 1943 bits
Bits Received (since last sync): 1943 Kbits
Direction : Line