3-4
Cisco MDS 9000 Family Troubleshooting Guide
OL-5183-02, Cisco MDS SAN-OS Release 1.3
Chapter 3 Troubleshooting Switch Level Issues and Interswitch Connectivity
Troubleshooting E Port Connectivity - ISL Isolation
Received 0 runts, 0 jabber, 0 too long, 0 too short
0 EOF abort, 0 fragmented, 0 unknown class
100 OLS, 67 LRR, 37 NOS, 0 loop inits
133283352 packets output, 1332969530 bytes
Transmitted 198 OLS, 50 LRR, 0 NOS, 10 loop inits
In this example the interface is indicating a link isolation caused by an ELP failure on an E port. The
ELP is a frame sent between two switches to negotiate fabric parameters. If you get this failure, verify
the fabric parameters are the same for both switches.
Since fabric parameters are configured on a per switch basis, however, they are required to be the same
for all switches within a fabric.
If the interface indicates an ELP failure verify the following parameters match using the show fctimer
command:
ED_TOV Timer
RA_TOV Timer
FS_TOV timer
An example of the show fctimer command where all default value are in use, is shown below
switch# show fctimer
F_S_TOV : 5000 milliseconds
D_S_TOV : 15000 milliseconds
E_D_TOV : 2000 milliseconds
R_A_TOV : 10000 milliseconds
Another parameter to check, is the Rcxbuffer size on the interface. This value should match on both the
ends of a ISL. To verify the value of the Rcxbuffer size, use the following command:
switch# show port internal info interface fc2/1
fc2/1 - if_index: 1080000
Admin Config - state(up), mode(Auto), speed(auto), trunk(no trunk)
beacon(off), snmp trap(on), tem(false)
bb_credit(default), rxbufsize(2112), encap(default)
description()
Operational Info - state(down), mode(ALL), speed(auto), trunk(no trunk)
state reason(Link failure or not-connected)
phy port enable (1), phy layer (FC)
participating(1), port_vsan(1), null_vsan(0), fcid(0x000000)
current state [PI_FSM_ST_LINK_INIT]
port_init_eval_flag(0x00000001), cfg wait for none
Mts node id 0x202
cnt_link_failure(0), cnt_link_success(0), cnt_port_up(0)
cnt_cfg_wait_timeout(0), cnt_port_cfg_failure(0), cnt_init_retry(0)
Port Capabilities -
Modes: E,TE,F,FL,TL,SD
Min Speed: 1000
Max Speed: 2000
Max Tx Bytes: 2112
Max Rx Bytes: 2112
Max Tx Buffer Credit: 255
Max Rx Buffer Credit: 16
Max Private Devices: 63
Max Sourcable Pkt Size: 2112
Hw Capabilities: 0xb
Connector Type: 0x0

Table of Contents

Other manuals for Cisco MDS 9000 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Cisco MDS 9000 Series and is the answer not in the manual?

Cisco MDS 9000 Series Specifications

General IconGeneral
CategorySwitch
Operating SystemCisco NX-OS
PortsVaries by model
ProtocolsFibre Channel (FC), Fibre Channel over IP (FCIP), iSCSI
RedundancyRedundant supervisors, power supplies, and fans
ManagementCisco Data Center Network Manager (DCNM), CLI, SNMP
Virtualization SupportVSANs (Virtual SANs)
Security FeaturesFibre Channel Security Protocol (FC-SP)
Hot Swappable Componentspower supplies, fans
Power Supply OptionsAC and DC options available

Related product manuals