3-14
Cisco MDS 9000 Family Troubleshooting Guide
OL-5183-02, Cisco MDS SAN-OS Release 1.3
Chapter 3 Troubleshooting Switch Level Issues and Interswitch Connectivity
Troubleshooting Fx Port Connectivity
0 frames output, 0 bytes, 0 discards
Received 0 OLS, 0 LRR, 0 NOS, 0 loop inits
Transmitted 0 OLS, 0 LRR, 0 NOS, 0 loop inits
Counter Values (5 minute averages):
0 frames input, 0 bytes, 0 discards
0 runts, 0 jabber, 0 too long, 0 too short
0 input errors, 0 CRC, 0 invalid transmission words
0 address id, 0 delimiter
0 EOF abort, 0 fragmented, 0 unknown class
0 frames output, 0 bytes, 0 discards
Received 0 OLS, 0 LRR, 0 NOS, 0 loop inits
Transmitted 0 OLS, 0 LRR, 0 NOS, 0 loop inits
Link_Failure or Not Connected
The following example shows the interface down as a result of a link failure or disconnect.
switch# show interface fc7/31
fc7/31 is down (Link_Failure or not connected)
Hardware is Fibre Channel
Port WWN is 21:9f:00:05:30:00:18:a2
Admin port mode is auto, trunk mode is on
vsan is 1
Beacon is turned off
Counter Values (current):
0 frames input, 0 bytes, 0 discards
0 runts, 0 jabber, 0 too long, 0 too short
0 input errors, 0 CRC, 0 invalid transmission words
0 address id, 0 delimiter
0 EOF abort, 0 fragmented, 0 unknown class
0 frames output, 0 bytes, 0 discards
Received 0 OLS, 0 LRR, 0 NOS, 0 loop inits
Transmitted 0 OLS, 0 LRR, 0 NOS, 0 loop inits
Counter Values (5 minute averages):
0 frames input, 0 bytes, 0 discards
0 runts, 0 jabber, 0 too long, 0 too short
0 input errors, 0 CRC, 0 invalid transmission words
0 address id, 0 delimiter
0 EOF abort, 0 fragmented, 0 unknown class
0 frames output, 0 bytes, 0 discards
Received 0 OLS, 0 LRR, 0 NOS, 0 loop inits
Transmitted 0 OLS, 0 LRR, 0 NOS, 0 loop inits
The message “Link_Failure” or “not connected” can happen if nothing is connected to the specific
interface (as in the case of a broken fiber), or if there is no bit synchronization between the switch
interface and the Nx port directly connected. (In the case of a broken fiber, if only the TX path from the
F port to the N port is broken, the switch interface will still have an operational Rx path, and so will still
obtain bit synchronization from the bit stream received from the N port. It will also be able to recognize
an incoming NOS from the N port and reply with an OLS. But because the transmitted OLS never
reaches the N port the R_T_TOV timer expires. In this scenario the status of the port will also show
"Link_Failure or not connected". )
The key difference between this case and the "no bit synchronization" case, is that the input and output
counts for OLS & NOS increment (as there is bit synchronization but no word synchronization). In such
a state, you can check that the Tx path from switch to the Rx input on N port interface is properly
connected. A faulty transmitter on the switch’s SFP or a faulty receiver on the N port’s SFP could also
cause the issue.

Table of Contents

Other manuals for Cisco MDS 9000 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Cisco MDS 9000 Series and is the answer not in the manual?

Cisco MDS 9000 Series Specifications

General IconGeneral
CategorySwitch
Operating SystemCisco NX-OS
PortsVaries by model
ProtocolsFibre Channel (FC), Fibre Channel over IP (FCIP), iSCSI
RedundancyRedundant supervisors, power supplies, and fans
ManagementCisco Data Center Network Manager (DCNM), CLI, SNMP
Virtualization SupportVSANs (Virtual SANs)
Security FeaturesFibre Channel Security Protocol (FC-SP)
Hot Swappable Componentspower supplies, fans
Power Supply OptionsAC and DC options available

Related product manuals