Table 24: Power Availability for 3.5-kW Inputs (DC)
FullRedundancyModeInput
SourceRedundancyMode
Power
SupplyRedundancyMode
CombinedModePower Inputs
3,500 W
3,500 W
7,000 W
3,500 W
3,500 W
7,000 W
3,500 W
7,000 W
10,500
3,500 W
7,000 W
10,500 W
14,000 W
Dual inputs per
power supply
14
380-V input
1 power supply
2 power supplies
3 power supplies
4 power supplies
3,500 W
3,500 W
7,000 W
3,500 W
3,500 W
7,000 W
3,500 W
7,000 W
10,500
3,500 W
7,000 W
10,500 W
14,000 W
220/240-V input
1 power supply
2 power supplies
3 power supplies
4 power supplies
3,100 W
3,100 W
6,200 W
3,100 W
3,100 W
6,200 W
3,100 W
6,200 W
9,300 W
3,100 W
6,200 W
9,300 W
12,400 W
210-V input
1 power supply
2 power supplies
3 power supplies
4 power supplies
14
The Cisco Nexus 7004 uses up to four 3.5 kW DC power supplies.
Table 25: Power Availability for 6.0-kW DC Power Supply Units
Full Redundancy
Mode
Input Source
Redundancy Mode
Power Supply
Redundancy Mode
Combined ModePower Inputs
6,000 W
9,000 W
12,000 W
3,000 W
6,000 W
9,000 W
12,000 W
6,000 W
12,000 W
18,000 W
6,000 W
12,000 W
18,000 W
24,000 W
Dual inputs per
power supply
1 power supply
2 power supplies 1
3 power supplies 1
4 power supplies 1
Cisco Nexus 7000 Series Hardware Installation and Reference Guide