SNMP
Configuring SNMP Notification Recipients
Cisco 220 Series Smart Switches Administration Guide Release 1.1.0.x 284
19
Configuring SNMPv1,2 Notification Recipients
Configuring SNMPv3 Notification Recipients
Configuring SNMPv1,2 Notification Recipients
To define a recipient in SNMPv1,2:
STEP 1 Click SNMP > Notification Recipients SNMPv1,2.
STEP 2 To create an SNMPv1,2 notification recipient, click Add.
STEP 3 Enter the following information:
Server Definition—Select whether to define the notification recipient by IP
address or name.
IP Version—Select either Version 4 or Version 6 if the notification recipient
is identified by IP address.
Recipient IP Address/Name—Enter the IP address or hostname of the
recipient that the traps are sent.
UDP Port—Enter the UDP port used for notifications on the recipient device.
Notification Type—Select whether to send Traps or Informs. If both are
required, two recipients must be created.
Timeout—Enter the number of seconds that the switch waits before re-
sending informs. The default is 15 seconds.
Retries—Enter the number of times that the switch resends an inform
request. The default is 3.
Community String—Select the SNMP community for the trap manager.
Notification Version—Select the trap SNMP version. Either SNMPv1 or
SNMPv2 may be used, with only a single version enabled at a single time.
STEP 4 Click Apply. The SNMPv1,2 notification recipient is defined, and the Running
Configuration is updated.

Table of Contents

Other manuals for Cisco SG220-26P

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Cisco SG220-26P and is the answer not in the manual?

Cisco SG220-26P Specifications

General IconGeneral
ModelSG220-26P
Ports26
PoE Ports24
Switching Capacity52 Gbps
Forwarding Rate38.69 Mpps
LayerLayer 2
Power SupplyInternal
VLANs Supported256
ManagementWeb-based GUI, SNMP
Operating Temperature0°C to 40°C
Storage Temperature-4°F to 158°F (-20°C to 70°C)
Operating Humidity10% to 90% non-condensing
Storage Humidity5% to 95% non-condensing
Dimensions440 x 44 x 257 mm
Weight3.3 kg

Related product manuals