Administration: Time Settings
Configuring SNTP Server
Cisco 220 Series Smart Switches Administration Guide Release 1.1.0.x 71
6
- WeekWeek within the month from which DST begins every year.
- Month—Month of the year in which DST begins every year.
- TimeThe time at which DST begins every year.
To—Enter the date when DST ends each year.
- Day—Day of the week on which DST ends every year.
- WeekWeek within the month from which DST ends every year.
- Month—Month of the year in which DST ends every year.
- TimeThe time at which DST ends every year.
STEP 6 Click Apply. The system time is defined, and the Running Configuration is updated.
Configuring SNTP Server
The switch can be configured to synchronize its system clock with an SNTP server
specified on the SNTP Settings page.
To specify an SNTP server by name, you must first configure DNS servers on the
switch and enable Main Clock Source (SNTP Servers) on the System Time page.
To add an SNTP server:
STEP 1 Click Administration > Time Settings > SNTP Settings.
STEP 2 Enter the following information:
Host Definition—Select whether to specify the SNTP server by IPv4
address or by host name.
SNTP Server IP Address/Name—Enter the IPv4 address or hostname of
the SNTP server.
SNTP Server Port—Enter the UDP port number to be specified in the SNTP
message headers. By default, the port number is the well-known IANA value
of 123.
STEP 3 Click Apply. The SNTP server is added, and the Running Configuration is updated.

Table of Contents

Other manuals for Cisco SG220-26P

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Cisco SG220-26P and is the answer not in the manual?

Cisco SG220-26P Specifications

General IconGeneral
ModelSG220-26P
Ports26
PoE Ports24
Switching Capacity52 Gbps
Forwarding Rate38.69 Mpps
LayerLayer 2
Power SupplyInternal
VLANs Supported256
ManagementWeb-based GUI, SNMP
Operating Temperature0°C to 40°C
Storage Temperature-4°F to 158°F (-20°C to 70°C)
Operating Humidity10% to 90% non-condensing
Storage Humidity5% to 95% non-condensing
Dimensions440 x 44 x 257 mm
Weight3.3 kg

Related product manuals