EasyManua.ls Logo

Cisco TelePresence DX70 - Xstatus Systemunit Hardware Monitoring Fan [N] Status; Xstatus Systemunit Hardware Temperature; Xstatus Systemunit Notifications Notification [N] Text; Xstatus Systemunit Notifications Notification [N] Type

Cisco TelePresence DX70
202 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
D15363.05 Cisco TelePresence DX70 and DX80 API Reference Guide CE9.2, NOVEMBER 2017.
Copyright © 2017 Cisco Systems, Inc. All rights reserved. 184
Cisco TelePresence DX70 and DX80
API Reference Guide
xStatus SystemUnit Hardware Monitoring Fan [n] Status
The feedback shows the speed (rpm) for the specified fan.
Requires user role: ADMIN, USER
Value space of the result returned:
String
Example:
xStatus SystemUnit Hardware Monitoring Fan 1 Status
*s SystemUnit Hardware Monitoring Fan 1 Status: "locked on 1096 rpm"
** end
xStatus SystemUnit Hardware Temperature
Shows the current maximum temperature (degree Celsius) measured in the codec/system.
Requires user role: ADMIN, USER
Value space of the result returned:
String
Example:
xStatus SystemUnit Hardware Temperature
*s SystemUnit Hardware Temperature: "64.0"
** end
xStatus SystemUnit Notifications Notification [n] Text
Lists text related to important system notifications. Notifications are issued e.g. when a system
was rebooted because of a software upgrade, or when a factory reset has been performed.
All the notifications can be removed from the list by issuing the xCommand SystemUnit
Notifications RemoveAll command.
Requires user role: ADMIN, USER
Value space of the result returned:
String
Example:
xStatus SystemUnit Notifications Notification 1 Text
*s SystemUnit Notifications Notification 1 Text: "OK"
** end
xStatus SystemUnit Notifications Notification [n] Type
Lists the system notification types. Notifications are issued e.g. when a system is rebooted
because of a software upgrade, or when a factory reset is performed.
FactoryResetOK: This value is returned after a successful factory reset.
FactoryResetFailed: This value is returned after a failed factory reset attempt.
SoftwareUpgradeOK: This value is returned after a successful software upgrade.
SoftwareUpgradeFailed: This value is returned after a failed software upgrade attempt.
RebootRequired: This value is returned when a reboot is required.
Other: This value is returned for any other notifications.
All the notifications can be removed from the list by issuing the xCommand SystemUnit
Notifications RemoveAll command.
Requires user role: ADMIN, USER
Value space of the result returned:
FactoryResetOK, FactoryResetFailed, SoftwareUpgradeOK, SoftwareUpgradeFailed,
RebootRequired, Other
Example:
xStatus SystemUnit Notifications Notification 1 Type
*s SystemUnit Notifications Notification 1 Type: SoftwareUpgradeOK
** end
xStatus SystemUnit ProductId
Shows the product identity.
Requires user role: ADMIN, USER
Value space of the result returned:
String
Example:
xStatus SystemUnit ProductId
*s SystemUnit ProductId: "Cisco TelePresence Codec SX80"
** end
Introduction
About the API
xConfiguration
Appendices
xCommand
xSt atus
xSt atus

Table of Contents

Other manuals for Cisco TelePresence DX70

Related product manuals